MTP / MPO-LC Breakout Patch Cable, Multimode OM3 10G Fiber
- Home
- Fiber Cable Assemblies
- Fiber Trunk Cables
- MTP / MPO-LC Breakout Patch Cable, Multimode OM3 10G Fiber
- General Details
- Spec
- Enquiry
- Related Products
FOCONEC produces MTP / MPO-LC Breakout Patch Cable, one end with MTP / MPO connectors pre-terminated, another end with LC connectors pre-terminated. By adding a breakout kit on the LC end, the fanout legs are harnessed up to 2.0mm in diameter.
Our MTP-LC or MPO-LC breakout patch cable is available in multimode OM3 or OM4 fiber. An Elite MTP connector is available for lower insertion loss. Customized fanout length and label mark to meet various installation environments.
All MTP / MPO fiber cables are factory terminated, tested, and widely used to connect with the current installed base of optical transmitters, receivers, MTP / MPO to LC patch panels, and fiber cassettes.
Features:
- 12, 24 cores pre-terminated MTP-LC fiber trunk cable
- Multimode OM3, OM4 fiber
- With breakout kit, Harnessed 2.0mm fanout legs
- Custom fanout length, staggering
- Serial number labeling, easy to install and manage
- 100% factory tested
- Complete test results available
Applications:
- Data Centers
- Building, Backbone Cabling
- Local Area Network
- Various kinds of testing and self-control system
Order Guide:
MTBC- | xxx | - | xxx | - | xxx | - | xx | - | xx | |
Connector A | Connector B | Fiber Mode | Cable Type | Length | ||||||
MTP | MTP male | SCU | SC/UPC | SM | SM 9/125 | 24 | 24 cores | 1M | 1 meter | |
MTPF | MTP female | SCA | SC/APC | SBI | SM bend insensititive | 12 | 12 cores | 2M | 2 meters | |
MPO | MPO male | LCU | LC/UPC | M1 | MM 62.5/125 | 24 | 24 cores | customized | ||
MPOF | MPO female | LCA | LC/APC | M2 | MM 50/125 | |||||
M3 | MM OM3 10Gig | |||||||||
M4 | MM OM4 10Gig | |||||||||
Attn: | 1. Fan out length could be 30cm to max 1.5m | |||||||||
2. Cable Jacket could be OFNR, OFNP, LSZH. | ||||||||||
3. Bend insensitive fibers include G657.A2, G657.A2, and G657.B2. | ||||||||||
4. Fanout legs could be same length, or custom staggered |
Applications:
- Data Centers
- Building, Backbone Cabling
- Local Area Network
- Various kinds of testing and self-control system
Order Guide:
MTBC- | xxx | - | xxx | - | xxx | - | xx | - | xx | |
Connector A | Connector B | Fiber Mode | Cable Type | Length | ||||||
MTP | MTP male | SCU | SC/UPC | SM | SM 9/125 | 24 | 24 cores | 1M | 1 meter | |
MTPF | MTP female | SCA | SC/APC | SBI | SM bend insensititive | 12 | 12 cores | 2M | 2 meters | |
MPO | MPO male | LCU | LC/UPC | M1 | MM 62.5/125 | 24 | 24 cores | customized | ||
MPOF | MPO female | LCA | LC/APC | M2 | MM 50/125 | |||||
M3 | MM OM3 10Gig | |||||||||
M4 | MM OM4 10Gig | |||||||||
Attn: | 1. Fan out length could be 30cm to max 1.5m | |||||||||
2. Cable Jacket could be OFNR, OFNP, LSZH. | ||||||||||
3. Bend insensitive fibers include G657.A2, G657.A2, and G657.B2. | ||||||||||
4. Fanout legs could be same length, or custom staggered |
MTP Connector:
Connector Type | Single Mode | Multi Mode | ||
(APC Polish) | (PC Polish) | |||
Fiber Count | 8, 12, 24 | 8, 12, 24 | ||
Fiber Type | G652D, G657A1 | OM1,OM2,OM3 etc. | ||
Max. Insertion Loss | Elite | Standard | Elite | Standard |
≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.60dB | |
Return Loss | ≥60 dB | NA | ||
Durability | ≥500 times | |||
Operating Temperature | -40℃~+80℃ | |||
Test Wavelength | 1310nm | |||
Insert-pull test | 1000 times<0.5 dB | |||
Interchange | <0.5 dB | |||
Anti-tensile force | 15kgf |
MTP / MPO Fiber Cassette Module, LGX Footprint
buy pre-terminated MTP/MPO fiber cassette module 24 port, MTP/LC patch cables, adapters fully loaded, suitable LGX fiber patch panel, enclosures.
MTP to MTP Fiber Patch Cable, OM3/OM4 10G 50/125, 12 Core
buy OM3/OM4 MTP to MTP Fiber Patch Cable 12 Strand, multimode OM3, OM4 10g fiber, high-speed data transmission, low insertion loss.
MPO Fiber Optic Adapters
buy MPO fiber optic adapter single-mode/multimode, plastic housing, couple 2 MPO or MTP connectors precisely